MV39 06 14 /V
MV39 06 14 /V

Raccordi a Funzione

rohs
temperatura
-20/+70 °C
pressione_esercizio
0/10 bar
filetto
G1/4
diametro
G1/4

Descrizione

Codice Prodotto 04290V32
Descrizione MV39 - Regolatore di Flusso
Tipo MV39 06 14 /V
Materiale Tecnopolimero
D1 G1/4
Tipologia filetto GAS UNI EN ISO 228-1
Temperatura di lavoro [°C] -20/+70 °C
Pressione di lavoro [bar] 0/10 bar
Campo di applicazione Pneumatic installations fed with filtered, lubricated air
D2 [mm] 12
D2 [in] .472
CH [mm] 17
Peso [g] 38
Peso [oz] 1.34
L1 [mm] 6,7
L1 [in] .264
L2 [mm] 27,2
L2 [in] 1.07
L4 [mm] 24,3
L4 [in] .957
L3 Max [mm] 39,5
L3 Max [in] 1.55
Øe Tubo [mm] 6
Pressione di lavoro [psi] 0/145 psi
Temperatura di lavoro [F] -4/158 °F
Conformità RoHS
Direzione Flusso IN

Varianti MV39

TYPE MAT D1 WT WP AF D2 D2IN CH G GOZ L1 L1IN L2 L2IN L4 L4IN L3MAX L3MAXIN TUBO WPP WTF CONF FLOW Code
MV39 04 18 /B Tecnopolimero G1/8 -20/+70 °C 0/10 bar Pneumatic installations fed with filtered, lubricated air 9,7 .382 14 20 0.705 5,1 .201 23,7 .933 19,1 .752 31,7 1.24 4 0/145 psi -4/158 °F RoHS BID 04290B11
MV39 04 18 /C Tecnopolimero G1/8 -20/+70 °C 0/10 bar Pneumatic installations fed with filtered, lubricated air 9,7 .382 14 20 0.705 5,1 .201 23,7 .933 19,1 .752 31,7 1.24 4 0/145 psi -4/158 °F RoHS OUT 04290C11
MV39 04 18 /V Tecnopolimero G1/8 -20/+70 °C 0/10 bar Pneumatic installations fed with filtered, lubricated air 9,7 .382 14 20 0.705 5,1 .201 23,7 .933 19,1 .752 31,7 1.24 4 0/145 psi -4/158 °F RoHS IN 04290V11
MV39 04 M5 /B Tecnopolimero M5x0,8 -20/+70 °C 0/10 bar Pneumatic installations fed with filtered, lubricated air 9,7 .382 8 7 0.247 4 .157 15,2 .598 17,6 .693 25 .984 4 0/145 psi -4/158 °F RoHS BID 04290B10
MV39 04 M5 /C Tecnopolimero M5x0,8 -20/+70 °C 0/10 bar Pneumatic installations fed with filtered, lubricated air 9,7 .382 8 7 0.247 4 .157 15,2 .598 17,6 .693 25 .984 4 0/145 psi -4/158 °F RoHS OUT 04290C10
MV39 04 M5 /V Tecnopolimero M5x0,8 -20/+70 °C 0/10 bar Pneumatic installations fed with filtered, lubricated air 9,7 .382 8 7 0.247 4 .157 15,2 .598 17,6 .693 25 .984 4 0/145 psi -4/158 °F RoHS IN 04290V10
MV39 06 14 /B Tecnopolimero G1/4 -20/+70 °C 0/10 bar Pneumatic installations fed with filtered, lubricated air 12 .472 17 38 1.34 6,7 .264 27,2 1.07 24,3 .957 39,5 1.55 6 0/145 psi -4/158 °F RoHS BID 04290B32
MV39 06 14 /C Tecnopolimero G1/4 -20/+70 °C 0/10 bar Pneumatic installations fed with filtered, lubricated air 12 .472 17 38 1.34 6,7 .264 27,2 1.07 24,3 .957 39,5 1.55 6 0/145 psi -4/158 °F RoHS OUT 04290C32
MV39 06 18 /B Tecnopolimero G1/8 -20/+70 °C 0/10 bar Pneumatic installations fed with filtered, lubricated air 12 .472 14 21 0.741 5,1 .201 23,7 .933 22,7 .894 31,7 1.24 6 0/145 psi -4/158 °F RoHS BID 04290B31
MV39 06 18 /C Tecnopolimero G1/8 -20/+70 °C 0/10 bar Pneumatic installations fed with filtered, lubricated air 12 .472 14 22 0.776 5,1 .201 23,7 .933 22,7 .894 31,7 1.24 6 0/145 psi -4/158 °F RoHS OUT 04290C31
MV39 06 18 /V Tecnopolimero G1/8 -20/+70 °C 0/10 bar Pneumatic installations fed with filtered, lubricated air 12 .472 14 22 0.776 5,1 .201 23,7 .933 22,7 .894 31,7 1.24 6 0/145 psi -4/158 °F RoHS IN 04290V31
MV39 06 M5 /B Tecnopolimero M5x0,8 -20/+70 °C 0/10 bar Pneumatic installations fed with filtered, lubricated air 12 .472 8 8 0.282 4 .157 15,2 .598 21,5 .846 25 .984 6 0/145 psi -4/158 °F RoHS BID 04290B30
MV39 06 M5 /C Tecnopolimero M5x0,8 -20/+70 °C 0/10 bar Pneumatic installations fed with filtered, lubricated air 12 .472 8 8 0.282 4 .157 15,2 .598 21,5 .846 25 .984 6 0/145 psi -4/158 °F RoHS OUT 04290C30
MV39 06 M5 /V Tecnopolimero M5x0,8 -20/+70 °C 0/10 bar Pneumatic installations fed with filtered, lubricated air 12 .472 8 8 0.282 4 .157 15,2 .598 21,5 .846 25 .984 6 0/145 psi -4/158 °F RoHS IN 04290V30
MV39 08 14 /B Tecnopolimero G1/4 -20/+70 °C 0/10 bar Pneumatic installations fed with filtered, lubricated air 14 .551 17 39 1.376 6,7 .264 27,2 1.07 24,6 .969 39,5 1.55 8 0/145 psi -4/158 °F RoHS BID 04290B42
MV39 08 14 /C Tecnopolimero G1/4 -20/+70 °C 0/10 bar Pneumatic installations fed with filtered, lubricated air 14 .551 17 39 1.376 6,7 .264 27,2 1.07 24,6 .969 39,5 1.55 8 0/145 psi -4/158 °F RoHS OUT 04290C42
MV39 08 14 /V Tecnopolimero G1/4 -20/+70 °C 0/10 bar Pneumatic installations fed with filtered, lubricated air 14 .551 17 39 1.376 6,7 .264 27,2 1.07 24,6 .969 39,5 1.55 8 0/145 psi -4/158 °F RoHS IN 04290V42
MV39 08 18 /B Tecnopolimero G1/8 -20/+70 °C 0/10 bar Pneumatic installations fed with filtered, lubricated air 14 .551 14 22 0.776 5,1 .201 23,7 .933 23 .906 31,7 1.24 8 0/145 psi -4/158 °F RoHS BID 04290B41
MV39 08 18 /C Tecnopolimero G1/8 -20/+70 °C 0/10 bar Pneumatic installations fed with filtered, lubricated air 14 .551 14 22 0.776 5,1 .201 23,7 .933 23 .906 31,7 1.24 8 0/145 psi -4/158 °F RoHS OUT 04290C41
MV39 08 18 /V Tecnopolimero G1/8 -20/+70 °C 0/10 bar Pneumatic installations fed with filtered, lubricated air 14 .551 14 22 0.776 5,1 .201 23,7 .933 23 .906 31,7 1.24 8 0/145 psi -4/158 °F RoHS IN 04290V41
MV39 08 38 /B Tecnopolimero G3/8 -20/+70 °C 0/10 bar Pneumatic installations fed with filtered, lubricated air 14 .551 20 67 2.363 7,4 .291 31 1.22 26,5 1.04 50 1.96 8 0/145 psi -4/158 °F RoHS BID 04290B43
MV39 08 38 /C Tecnopolimero G3/8 -20/+70 °C 0/10 bar Pneumatic installations fed with filtered, lubricated air 14 .551 20 67 2.363 7,4 .291 31 1.22 26,5 1.04 50 1.96 8 0/145 psi -4/158 °F RoHS OUT 04290C43
MV39 08 38 /V Tecnopolimero G3/8 -20/+70 °C 0/10 bar Pneumatic installations fed with filtered, lubricated air 14 .551 20 67 2.363 7,4 .291 31 1.22 26,5 1.04 50 1.96 8 0/145 psi -4/158 °F RoHS IN 04290V43
MV39 10 14 /B Tecnopolimero G1/4 -20/+70 °C 0/10 bar Pneumatic installations fed with filtered, lubricated air 16 .63 17 39 1.376 6,7 .264 27,2 1.07 27 1.06 39,5 1.55 10 0/145 psi -4/158 °F RoHS BID 04290B52
MV39 10 14 /C Tecnopolimero G1/4 -20/+70 °C 0/10 bar Pneumatic installations fed with filtered, lubricated air 16 .63 17 39 1.376 6,7 .264 27,2 1.07 27 1.06 39,5 1.55 10 0/145 psi -4/158 °F RoHS OUT 04290C52
MV39 10 14 /V Tecnopolimero G1/4 -20/+70 °C 0/10 bar Pneumatic installations fed with filtered, lubricated air 16 .63 17 39 1.376 6,7 .264 27,2 1.07 27 1.06 39,5 1.55 10 0/145 psi -4/158 °F RoHS IN 04290V52
MV39 10 38 /B Tecnopolimero G3/8 -20/+70 °C 0/10 bar Pneumatic installations fed with filtered, lubricated air 16 .63 20 68 2.399 7,4 .291 31 1.22 28,5 1.12 50 1.96 10 0/145 psi -4/158 °F RoHS BID 04290B53
MV39 10 38 /C Tecnopolimero G3/8 -20/+70 °C 0/10 bar Pneumatic installations fed with filtered, lubricated air 16 .63 20 68 2.399 7,4 .291 31 1.22 28,5 1.12 50 1.96 10 0/145 psi -4/158 °F RoHS OUT 04290C53
MV39 10 38 /V Tecnopolimero G3/8 -20/+70 °C 0/10 bar Pneumatic installations fed with filtered, lubricated air 16 .63 20 68 2.399 7,4 .291 31 1.22 28,5 1.12 50 1.96 10 0/145 psi -4/158 °F RoHS IN 04290V53