PV41 1/4 1/8 /V
PV41 1/4 1/8 /V

Raccordi a Funzione "Pollici/NPT"

rohs
temperatura
-20/+70 °C
pressione_esercizio
0/10 bar
filetto
NPT1/8
diametro
1/8

Descrizione

Codice Prodotto 24310V31
Descrizione PV41 - Regolatore di Flusso
Tipo PV41 1/4 1/8 /V
Materiale Ottone nichelato
D1 1/8
Tipologia filetto NPT ANSI/ASME B 1.20.3
Temperatura di lavoro [°C] -20/+70 °C
Pressione di lavoro [bar] 0/10 bar
Campo di applicazione Pneumatic installations fed with filtered, lubricated air
D2 [mm] 12
D2 [in] .472
Peso [g] 38
Peso [oz] 1.34
HEX [mm] 9/16
L1 [mm] 8,2
L1 [in] .323
L2 [mm] 21,2
L2 [in] .835
L4 [mm] 51,8
L4 [in] 2.03
L3 Max [mm] 22,5
L3 Max [in] .886
Tubo O.D.[in] 1/4
Pressione di lavoro [psi] 0/145 psi
Temperatura di lavoro [F] -4/158 °F
Conformità RoHS
Direzione Flusso IN

Varianti PV41

TYPE MAT D1 WT WP AF D2 D2IN G GOZ HEX L1 L1IN L2 L2IN L4 L4IN L3MAX L3MAXIN OD WPP WTF CONF FLOW Code HEXIN
PV41 1/4 1/4 /B Ottone nichelato 1/4 -20/+70 °C 0/10 bar Pneumatic installations fed with filtered, lubricated air 12 .472 66,5 2.346 11/16 12,7 .5 26,7 1.05 61,1 2.40 24 .945 1/4 0/145 psi -4/158 °F RoHS BID 24310B32 ---
PV41 1/4 1/4 /C Ottone nichelato 1/4 -20/+70 °C 0/10 bar Pneumatic installations fed with filtered, lubricated air 12 .472 66,5 2.346 11/16 12,7 .5 26,7 1.05 61,1 2.40 24 .945 1/4 0/145 psi -4/158 °F RoHS OUT 24310C32 ---
PV41 1/4 1/4 /V Ottone nichelato 1/4 -20/+70 °C 0/10 bar Pneumatic installations fed with filtered, lubricated air 12 .472 66,5 2.346 11/16 12,7 .5 26,7 1.05 61,1 2.40 24 .945 1/4 0/145 psi -4/158 °F RoHS IN 24310V32 ---
PV41 1/4 1/8 /B Ottone nichelato 1/8 -20/+70 °C 0/10 bar Pneumatic installations fed with filtered, lubricated air 12 .472 37,5 1.323 9/16 8,2 .323 21,2 .835 51,8 2.03 22,5 .886 1/4 0/145 psi -4/158 °F RoHS BID 24310B31 ---
PV41 1/4 1/8 /C Ottone nichelato 1/8 -20/+70 °C 0/10 bar Pneumatic installations fed with filtered, lubricated air 12 .472 38 1.34 9/16 8,2 .323 21,2 .835 51,8 2.03 22,5 .886 1/4 0/145 psi -4/158 °F RoHS OUT 24310C31 ---
PV41 3/8 1/4 /B Ottone nichelato 1/4 -20/+70 °C 0/10 bar Pneumatic installations fed with filtered, lubricated air 16 .63 70 2.469 11/16 12,7 .5 26,7 1.05 61,1 2.40 26,5 1.04 3/8 0/145 psi -4/158 °F RoHS BID 24310B52 ---
PV41 3/8 1/4 /C Ottone nichelato 1/4 -20/+70 °C 0/10 bar Pneumatic installations fed with filtered, lubricated air 16 .63 70 2.469 11/16 12,7 .5 26,7 1.05 61,1 2.40 26,5 1.04 3/8 0/145 psi -4/158 °F RoHS OUT 24310C52 ---
PV41 3/8 1/4 /V Ottone nichelato 1/4 -20/+70 °C 0/10 bar Pneumatic installations fed with filtered, lubricated air 16 .63 70 2.469 11/16 12,7 .5 26,7 1.05 61,1 2.40 26,5 1.04 3/8 0/145 psi -4/158 °F RoHS IN 24310V52 ---
PV41 5/16 1/4 /B Ottone nichelato 1/4 -20/+70 °C 0/10 bar Pneumatic installations fed with filtered, lubricated air 14 .551 66,5 2.346 11/16 12,7 .5 26,7 1.05 61,1 2.40 24,5 .965 5/16 0/145 psi -4/158 °F RoHS BID 24310B42 ---
PV41 5/16 1/4 /C Ottone nichelato 1/4 -20/+70 °C 0/10 bar Pneumatic installations fed with filtered, lubricated air 14 .551 66,5 2.346 11/16 12,7 .5 26,7 1.05 61,1 2.40 24,5 .965 5/16 0/145 psi -4/158 °F RoHS OUT 24310C42 ---
PV41 5/16 1/4 /V Ottone nichelato 1/4 -20/+70 °C 0/10 bar Pneumatic installations fed with filtered, lubricated air 14 .551 66,5 2.346 11/16 12,7 .5 26,7 1.05 61,1 2.40 24,5 .965 5/16 0/145 psi -4/158 °F RoHS IN 24310V42 ---
PV41 5/16 1/8 /B Ottone nichelato 1/8 -20/+70 °C 0/10 bar Pneumatic installations fed with filtered, lubricated air 14 .551 38,5 1.358 9/16 8,2 .323 21,2 .835 51,8 2.03 23 .906 5/16 0/145 psi -4/158 °F RoHS BID 24310B41 ---
PV41 5/16 1/8 /C Ottone nichelato 1/8 -20/+70 °C 0/10 bar Pneumatic installations fed with filtered, lubricated air 14 .551 38,5 1.358 9/16 8,2 .323 21,2 .835 51,8 2.03 23 .906 5/16 0/145 psi -4/158 °F RoHS OUT 24310C41 ---
PV41 5/16 1/8 /V Ottone nichelato 1/8 -20/+70 °C 0/10 bar Pneumatic installations fed with filtered, lubricated air 14 .551 38,5 1.358 9/16 8,2 .323 21,2 .835 51,8 2.03 23 .906 5/16 0/145 psi -4/158 °F RoHS IN 24310V41 ---
PV41 5/32 1/8 /B Ottone nichelato 1/8 -20/+70 °C 0/10 bar Pneumatic installations fed with filtered, lubricated air 9,5 .374 37 1.305 9/16 8,2 .323 21,2 .835 51,8 2.03 20,5 .807 5/32 0/145 psi -4/158 °F RoHS BID 24310B11 ---
PV41 5/32 1/8 /C Ottone nichelato 1/8 -20/+70 °C 0/10 bar Pneumatic installations fed with filtered, lubricated air 9,5 .374 37 1.305 9/16 8,2 .323 21,2 .835 51,8 2.03 20,5 .807 5/32 0/145 psi -4/158 °F RoHS OUT 24310C11 ---
PV41 5/32 1/8 /V Ottone nichelato 1/8 -20/+70 °C 0/10 bar Pneumatic installations fed with filtered, lubricated air 9,5 .374 37 1.305 9/16 8,2 .323 21,2 .835 51,8 2.03 20,5 .807 5/32 0/145 psi -4/158 °F RoHS IN 24310V11 ---
PV41 5/32 10-32 /B Ottone nichelato 10-32 -20/+70 °C 0/10 bar Pneumatic installations fed with filtered, lubricated air 9,5 .374 13 0.459 6 5 .197 13,5 .531 40,5 1.59 18,5 .728 5/32 0/145 psi -4/158 °F RoHS BID 24310B10 0,236
PV41 5/32 10-32 /C Ottone nichelato 10-32 -20/+70 °C 0/10 bar Pneumatic installations fed with filtered, lubricated air 9,5 .374 13 0.459 6 5 .197 13,5 .531 40,5 1.59 18,5 .728 5/32 0/145 psi -4/158 °F RoHS OUT 24310C10 0,236
PV41 5/32 10-32 /V Ottone nichelato 10-32 -20/+70 °C 0/10 bar Pneumatic installations fed with filtered, lubricated air 9,5 .374 13 0.459 6 5 .197 13,5 .531 40,5 1.59 18,5 .728 5/32 0/145 psi -4/158 °F RoHS IN 24310V10 0,236